					Icon code | 
				
					Design size | 
				
					Tolerance | 
			
| 
					A | 
				
					15.90 | 
				
					Minimum value | 
			
| B | 
					27.60 | 
				
					The maximum value | 
			
| C | 
					1.75 | 
				
					Minimum value | 
			
| D | 
					21.50 | 
				
					Reference | 
			
| E | 
					18.00 | 
				
					Reference | 
			
| F | 
					1.00 | 
				
					±0.10 | 
			
| G | 
					37.30 | 
				
					The maximum value | 
			
| H | 
					29.20 | 
				
					±0.30 | 
			
| I | 
					1.50 | 
				
					±0.10 | 
			
| J | 
					2.00 | 
				
					±0.10 | 
			
| W | 
					1.00 | 
				
					Reference | 
			
● Detection tool: digital caliper or micrometer.
● Indicate the code for inspection.
● The number of outlet slots is 4 × 2.
● hole A is not roundness ≤ 0.20mm, both sides of the hobbing plane of the parallelism ≤ 0.20mm, no significant warping.
● hole hole anastomosis is not allowed to have a step, feel smooth and unimpeded.
● no residual shape or damage, color is no different normal
● finish up to ▽ 7 or more, but allow for harmless scars and miniatures.
● Metal-free impurities or other debris, containing metal, debris products, must be waste separation.
● no melting marks, no internal pores bright spot. There are stomatal highlights (excluding melting marks) products for foreign goods.
● no flash, burr and excess material. Key parts of the burr ≤ 0.05 mm.
● anti-pressure ≥ 25 kg / square centimeter, no damage.
● feel a strong elasticity, and not brittle.
● hardness, wear resistance are suitable for high-speed heavy-duty rotation.
● Selection of raw materials must meet the requirements of the EU ROHS directive, and has UL yellow card certification and fixed-point supply.
● heat distortion temperature ≥ 120 degrees Celsius, insulation resistance must be ≥ 1000M ohm, flame retardant UL94Vo level / 0.8-3.2mm.
● other structures should meet the transformer manufacturing process as the standard.
	
	
 
Check the main design dimensions as shown: R-07 outside
| 
					Icon code | 
				
					Design size | 
				
					Tolerance | 
			
| K | 21.80 | ± | 
| L | 27.50 | The maximum value | 
| M | 1.85 | Minimum value | 
| N | 23.80 | ± | 
| O | 1.00 | ±0.10 | 
| P | 32.50 | ± | 
| Q | 27.00 | ±0.30 | 
| R | 1.50 | ± | 
| S | 2.50 | ± | 
● Detection tool: digital caliper or micrometer.
● Indicate the code for inspection.
● The number of outlet slots is 5 × 2.
● the hole K is not roundness ≤ 0.20mm, with the inner shell D size with the appropriate fit.
● hole hole anastomosis is not allowed to have a clear step, two pieces of flat after no obvious warping, splicing seam ≤ 0.20mm.
● shape no defect or damage, allowing anastomosis in the absence of defects, color is no different normal
● finish up to ▽ 7 or more, but allow for harmless scars and miniatures.
● Metal-free impurities or other debris, containing metal, debris products, must be waste separation.
● no melting marks, no internal pores bright spot. There are stomatal highlights (excluding melting marks) products for foreign goods.
● no flash, burr and excess material. Key parts of the burr ≤ 0.05 mm.
● anti-pressure ≥ 25 kg / square centimeter, no damage.
● feel a strong elasticity, and not brittle.
● Selection of raw materials must meet the requirements of the EU ROHS directive, and has UL yellow card certification and fixed-point supply.
● heat distortion temperature ≥ 120 degrees Celsius, insulation resistance must be ≥ 1000M ohm, flame retardant UL94Vo level / 0.8-3.2mm.
● other structures should meet the transformer manufacturing process as the standard.
	